The new power in energy! | Installation Cables and Flexible Cables

U-1000 RVFV

U-1000 RVFV

XP C 32-321

U-1000 RVFV
Construction
1
İletken: Som veya Örgülü Bakır
2
İzole: XLPE İzolasyon
3
Dolgu: PVC Dolgu
4
Zırh: Çift Çelik Bant
5
Dış Kılıf: PVC Kılıf
Application Areas

The color-coded sheath enables 1.5-16 mm² sizing without measurement. UV resistance allows use in all weather conditions without additional protection.

Standards
  •   XP C 32-321
Technical Specifications
Permissible Operating Temperature 90 °C
Short Circuit Temperature 250 °C
Test Voltage (AC) 4 kV
Minimum Installation Temperature 5 °C
Minimum Bending Radius 15xD
Rated Voltage 0.6/1 kV
Conductor Solid or stranded copper
Insulation XLPE
Filler PVC
Armour Double steel tape
Sheath PVC
Technical Data
Rated Cross-section Overall Diameter of Cable (Approx) Current Carrying Capacity Conductor DC Resistance at 20°C Net Weight (Approx) Amount of Packing
Air Ground
mm² mm A A ohm/km kg/km m
2 x 10 18,64 86 104 1,83 1020,4 1000
2 x 16 20,70 115 136 1,15 1267,4 1000
2 x 25 24,20 149 173 0,727 1688,0 1000
3 x 10 19,49 75 87 1,83 1151,3 1000
3 x 16 21,72 100 113 1,15 1455,9 1000
3 x 25 25,50 127 144 0,727 1967,5 1000
3 x 35 27,90 158 174 0,524 2404,1 1000
3 x 50 31,23 192 206 0,387 2976,5 1000
3 x 70 36,84 246 254 0,268 4384,8 1000
3 x 95 41,61 308 306 0,193 5611,1 500
3 x 120 45,08 358 347 0,153 6692,6 500
3 x 150 49,78 413 393 0,124 8047,2 500
3 x 185 54,98 476 444 0,0991 9778,0 250
3 x 240 61,17 565 518 0,0754 12248,3 250
4 x 10 21,01 75 87 1,83 1330,9 1000
4 x 16 23,38 100 113 1,15 1706,6 1000
4 x 25 27,83 132 144 0,727 2340,8 1000
4 x 35 31,07 158 174 0,524 2888,7 1000
4 x 50 35,07 192 206 0,387 3604,7 1000
4 x 70 41,39 246 254 0,268 5310,7 500
4 x 95 47,07 298 301 0,193 6918,1 500
4 x 120 50,95 358 347 0,153 8296,1 500
4 x 150 56,36 413 393 0,124 10011,0 250
4 x 185 63,16 476 444 0,0991 12212,9 250
4 x 240 70,37 565 518 0,0754 15373,4 250
5 x 10 22,39 75 87 1,83 1525,1 1000
5 x 16 25,17 100 113 1,15 1976,9 1000
5 x 25 30,14 132 144 0,727 2749,8 1000
3 x 35+16 28,45 158 174 0.524/1.150 1899,9 1000
3 x 50+25 24,60 192 206 0.387/0.727 2495,2 1000
3 x 50+35 25,12 192 206 0.387/0.524 3369,5 1000
3 x 70+35 36,47 246 254 0.268/0.524 3534,3 1000
3 x 70+50 37,39 246 254 0.268/0.387 3527,9 1000
3 x 95+50 41,54 308 305 0.193/0.387 4507,9 500
3 x 120+70 45,66 346 358 0.153/0.268 5635,7 500
3 x 150+70 49,58 399 412 0.124/0.268 6647,5 500
3 x 185+70 53,90 476 444 0.0991/0.268 7963,7 250
3 x 185+95 55,07 476 444 0.0991/0.193 8307,9 250
3 x 240+95 60,22 538 501 0.754/0.193 10250,4 250

U-1000 RVFV is a 0.6/1 kV power cable compliant with XP C 32-321, featuring a solid or stranded copper conductor, XLPE insulation, PVC filler, double steel tape armour and PVC sheath. It is rated for 90 °C operating temperature, 250 °C short-circuit temperature, 4 kV AC test voltage, minimum 5 °C installation temperature and 15xD minimum bending radius.